36+ years. 1,000+ boilers installed. Gas Safe registration No. 575142.
We've been looking after heating systems across Sussex and Surrey since 1988. One question homeowners often ask is a fair one: what does a boiler service include, exactly?
It should be more than switching the boiler on and glancing at the display. A proper service follows the manufacturer's instructions and checks the appliance's condition, operation and safety. Here's what we do, step by step, and what you should expect from a visit.

Before the Service: What Should You Prepare?
For a straightforward combi boiler, allow roughly 30–60 minutes. A system boiler or back boiler can take longer, depending on its design, access and condition.
You can help the visit go smoothly by:
- Making sure the engineer can reach the boiler and its controls.
- Clearing items from the cupboard or area around it.
- Finding any previous service records and the boiler manual, if you have them.
- Telling the engineer about unusual noises, error messages or changes in performance.
Where possible, have the boiler switched off and cool before the appointment. The engineer may need to open the casing to inspect components, and a cool appliance makes that work more practical. They may run the boiler during the service to check how it operates.
Step 1: The Boiler Casing, Controls and Visible Condition
The engineer starts with the appliance itself. They look at the casing and accessible pipework for signs of damage, corrosion, leaks or other issues. They also check the controls and, where appropriate, run the boiler to see that it starts, operates and responds as expected.
This is a chance to raise small concerns you've noticed. A change in sound or a recurring fault code may help the engineer understand what to look at more closely.

Step 2: Flue and Ventilation Checks
The flue carries combustion products safely outside. The engineer checks the accessible flue and its termination for visible damage, obstruction or signs that something may be wrong. They also check that the boiler has the ventilation it requires.
These checks matter because the flue and ventilation are part of the appliance's safe operation. If something needs further investigation, the engineer should explain what they found and what needs to happen next.
Step 3: Gas Pressure and Gas Rate
The engineer checks gas pressure and gas rate as appropriate for the boiler and its manufacturer's servicing procedure. These measurements help show whether the appliance is receiving gas and operating as expected.
They're not a substitute for checking combustion, which is why a service should also include flue gas analysis.
Step 4: Combustion Analysis With a Flue Gas Analyser
With the boiler operating as required, the engineer uses a flue gas analyser to check combustion. The analyser measures the gases leaving the boiler and provides readings that help assess how the appliance is burning fuel.
This is a technical check, not something you can judge by looking at the boiler display. The engineer should take and note relevant readings, follow the appliance's procedure and explain anything that falls outside the expected range.
Step 5: Burner, Heat Exchanger, Seals and Gaskets
Where the boiler's instructions call for it, the engineer removes the casing to inspect internal parts. They check the condition of the burner and heat exchanger, and look at seals and gaskets for signs of wear or damage.
What gets cleaned or dismantled depends on the boiler model, its condition and the manufacturer's instructions. A service is not a reason to take every component apart regardless of need. If a part is worn or a repair is recommended, you should be told what the issue is and why it matters.
Step 6: Condensate Trap, Pipe and Safety Devices
On a condensing boiler, the engineer checks the condensate trap and pipe for problems such as blockage, and cleans the trap where required by the service procedure. It should be correctly refitted after inspection.
The engineer also checks the boiler's relevant safety devices and controls. These help the appliance operate within its designed limits and shut down safely if something is wrong. The precise checks depend on the make and model.
Step 7: Service Record and Clear Advice
At the end, the engineer should leave you with a written service record, any relevant readings noted, and a clear explanation of anything flagged.
If further work is needed, a service itself does not automatically authorise a repair. You should understand what has been found, what the repair involves and what it will cost before deciding whether to go ahead. We'll give you an honest view if a repair looks poor value compared with replacing an ageing boiler. You can also read our guides to new boiler costs in the UK and our boiler installation service if replacement becomes part of the conversation.
What a Boiler Service Is Not
A service is a scheduled check and maintenance visit. It is not:
- A repair. A fault may be discovered, but diagnosis or repair work may need to be discussed and agreed separately.
- A Gas Safety inspection. They are different types of visit, with different purposes.
- A system flush or power flush. That is separate work and is not automatically included in a boiler service.
A service is also not an MOT with a simple pass-or-fail outcome. The point is to check safety and operation, record what the engineer finds and identify signs of wear early. If there is a safety concern, the engineer should explain it plainly and advise what action is needed.
Why Annual Servicing Matters for Your Boiler Warranty
Many manufacturers make annual servicing by a Gas Safe registered engineer a condition of their warranty or guarantee. The exact requirements vary by boiler and warranty terms, so check the paperwork for your own model and keep the service record.
We service Vaillant, Glow-worm, Baxi and Ideal boilers. Whatever the make, the engineer should follow its servicing instructions rather than rely on a one-size-fits-all checklist.
Looking for a Gas Boiler Service Near You?
If you're searching for a gas boiler service near me or a Gas Safe engineer in Sussex, ask what the visit includes before booking. In particular, check whether the engineer will inspect the flue, check gas pressure or rate, carry out combustion analysis and provide a written record.
Our local team serves East Sussex, West Sussex and Surrey, including areas around Brighton, Worthing, Horsham, Lewes and Crawley. We're not a call centre. We're local engineers who have been doing the work since 1988, with more than 1,000 boilers installed.
To understand what affects the bill, see our boiler service cost guide for 2026. The right service is about knowing what's included and getting a clear answer if the engineer finds a problem.

Frequently Asked Questions
- How long does a boiler service take?
- For a straightforward combi boiler, allow roughly 30–60 minutes. A system boiler or back boiler can take longer, depending on its design, access and condition.
- What does a boiler service include?
- A proper service follows the manufacturer’s instructions. It typically covers the casing, controls and visible condition, flue and ventilation checks, gas pressure and gas rate, combustion analysis with a flue gas analyser, the burner, heat exchanger, seals and gaskets where required, the condensate trap and safety devices, and a written service record.
- Is a boiler service the same as a repair or a power flush?
- No. A service is a scheduled check and maintenance visit. A fault may be discovered, but repair work may need to be discussed and agreed separately. A system flush or power flush is separate work and is not automatically included.
- Do I need an annual service to keep my boiler warranty?
- Many manufacturers make annual servicing by a Gas Safe registered engineer a condition of their warranty or guarantee. The exact requirements vary by boiler and warranty terms, so check the paperwork for your own model and keep the service record.
A Clear Service, With No Hard Sell
A good service should leave you knowing what was checked, what the readings showed and whether anything needs attention. That's the standard we aim for: do the work properly, explain the findings and let you decide what to do next.
If your boiler is due a service, talk to our Gas Safe registered team, No. 575142. No hard sell. Just a straight conversation about what your boiler needs.